50w 70w Fractional Co2 Laser Machine for Skin
Product Description
Laser System: Fractional / Normal / Gynae / Vulvae
Power: 70w / 100w Import from USA
Handle: Smart Scan head
Motor: German photoelectric diffuse reflection nano soft magnetic alloy material sensor
Light Guide Arm: 7-section light guide arm from Korea
Voltage: 110V/220V 50HZ/60HZ
Scanning Launch Model: positive, reverse, out
Function: Skin rejuvenation,vaginal rejuvenation,scar removal
Spot Distance: 0.1mm-2.6mm(adjustable)
Scan Times: 1-20 times
Stand-by Working: Continuously for more than 18 hours
Scan Size: Up to 20x20mm
Scan Shapes: Squrar, Rectangle, Circle, Triangle, Rhombus, Ellipse,Line
CO2 fractional laser machine, It works by delivering short pulses of high-energy laser light to the skin, creating tiny columns of thermal damage. This stimulates the body’s natural healing response, promoting collagen production and cell turnover, resulting in smoother, more even-toned skin.
Introducing of Fraxco2® FC100
Co2 Fractional Laser-Under a certain energy density, the laser beam can penetrate through the epidermis and enter the dermis. Since the absorption is relatively good, the thermal energy generated by the tissue in the part where the laser passes through absorbing the laser energy will lead to columnar thermal degeneration of the part. Area. Along with this process, all layers in the skin are rebuilt: a certain degree of exfoliation of the epidermis, new collagen from the dermis, etc.
Principle
Co2 Fractional Laser-Laser technology based on this principle is also known as lattice laser and pixel laser. It is a new technology that transforms the emission mode of traditional laser into pixel mode. Compared with traditional lasers, pixel lasers change the emission mode of light, and control the originally small laser beams through a scanner and a space lens matrix into even smaller laser beams, which act on the skin to generate hundreds of thousands of laser beams. Microporous hot zone.
Technology
Co2 Fractional Laser-Completely different from the previous traumatic and non-ablative skin rejuvenation, the establishment and further clinical application of this new technology allow us to avoid the problem of long recovery time and low safety in traumatic treatment, and overcome the problem of non-ablative skin rejuvenation. The weak point of poor technical efficacy is somewhere in between, thus establishing a safe and efficient means of skin rejuvenation.
USA Coherent Laser
*. Imported by Coherent Company in the United States, the laser tube performance is stable.
*. There is no life limit, the metal material is sturdy and durable, and the reliability is super
*. High peak power, short pulse rising edge time, and high pulse modulated frequency, which can effectively improve processing efficiency and accuracy
Smart Scan Head
*. Using imported motors from Germany, the power consumption is reduced
*. Added anti-leakage and light-blocking design for safer operation
*. The material abandons the previous metal materials, reforms and innovates, and uses ABS material, which has the characteristics of anti-shielding, anti-static, high and low temperature resistance, etc.
*. The appearance is the first in China, the exquisite geometric streamline design makes the appearance smooth and generous, comfortable and convenient to hold, and the operation is more free
*. The 70W intelligent scanning head has added the function of button intelligent operation. It is the first innovative new function design in the industry. When hand-held operation, you can directly switch the shape of the graphics, adjust the size of the graphics, and prepare for operation, making it easier to use. It is convenient and fast, reducing the operation time of customers.
Datasheet
| Brand | FRAXCO2 |
| Manufacture | WINKONLASER |
| OEM/ODM | YES |
| LOGO | Free Design |
FAQ
Winkonlaser manufactures the FraxCO₂ FC100 fractional CO₂ laser platform. Request a quotation identifying the current laser power version, source specification and compatible scan head. The page title and product description list different power options, so the configuration sheet should confirm which version is being supplied and which accessories and functions it supports.
The FC100 page describes on-head buttons for changing the scan pattern, adjusting its size and preparing the system for operation on the 70 W scanning-head version. Listed patterns include square, rectangle, circle, triangle, rhombus, ellipse and line, with a scan field up to 20 × 20 mm. Confirm these controls on the head supplied with your selected configuration and request a demonstration during training.
The product description lists Fractional, Normal, Gynae and Vulvae system labels, but it does not provide a complete accessory packing list. Ask the quotation to identify enabled modes, included handpieces and optional probes separately. Any specialized application must be supported by the instructions and applicable authorization for the exact configuration; a mode name alone does not establish that its accessories are included or its use is permitted in every market.
The FC100 product description lists a 110 V / 220 V, 50/60 Hz supply and a seven-section light-guide arm. Obtain the delivered unit’s nameplate and installation sheet to confirm voltage version, rated electrical input, circuit and site requirements. Request service instructions for the laser source, optical arm and scanner, together with maintenance intervals, replacement-part availability and warranty coverage. Laser-source durability should not be interpreted as an unlimited-life or maintenance-free guarantee.
Request the FC100 specification, instructions for use and regulatory documents covering your selected power version, handpieces and intended services in the destination market. Check the legal manufacturer, model and scope of each document. Training should cover client screening, laser safety, scanner controls, accessory handling, maintenance and aftercare. Ask for evidence relevant to any treatment or recovery-time claims you intend to use in your marketing.
Yes. The FC100 datasheet lists OEM/ODM availability and free logo design. Provide your destination, quantity, required power version, scan head and branding requirements for a written proposal. Have it specify standard and optional accessories, training, warranty, service costs and freight, together with MOQ, payment terms and production and transit times. Free logo design does not establish that all physical customization is included without charge. Send an FC100 enquiry.